Test Code LAB7757 Neutrophil Oxidative Burst
Performing Section
Immunology/Flow
Purpose/Principle
The Neutrophil Oxidative Burst (NOB) assay is used to support the diagnosis of X-linked Chronic Granulomatous Disease (XL-CGD), XL-CGD carriers, and autosomal recessive forms of CGD (AR-CGD). The NOB assay can also be used as a monitoring tool for success of engraftment following hematopoietic or stem cell transplant for CGD. The NOB assay is also useful for assessment of neutrophil function in patients with Glycogen Storage Disease type 1b (GSD-1b) pre- and post-therapy.
Special Collection Notes
No Gel.
Mix sample well after collection to prevent specimen clotting.
Specimen Type
Whole Blood:
Purple Top-EDTA (Preferred)
Dark Green Top-Sodium Heparin
Light Green Top-Lithium Heparin
Specimen Volume
Preferred: 3.0 mL
Minimum: 0.5 mL
Processing Instructions
Submit whole blood -DO NOT CENTRIFUGE.
Store and send ambient.
Sample must received into the lab Monday-Friday(before noon). Do not send sample on Friday (after noon), Saturday, Sunday or holidays.
Temperature
Ambient
Test Components
NOB Result
Reference Range
Normal
TAT
24 hours
Sample Stability
Ambient: 24 hours
Additional Notes
Testing must be performed within 24 hours.
Aliases
DHR 123
DHR
NOB
CPT
86352
Test/Batch Schedule
Monday-Friday Noon
Method
Flow Cytometry