Sign in →

Test Code LAB5176 Lyme Disease Antibody, Immunoblot, Serum

Additional Codes

LYWB

Reporting Name

Lyme Disease Ab, Immunoblot, S

Useful For

Aiding in the diagnosis of systemic Lyme disease

 

This test should not be used as a screening assay.

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume:0.75 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 14 days
  Frozen  30 days

Reference Values

IgG: Negative

IgM: Negative

Reference values apply to all ages

Day(s) Performed

Monday, Wednesday, Friday

CPT Code Information

86617 x 2

Testing Algorithm

For information see Acute Tick-Borne Disease Testing Algorithm.

Report Available

Same day/1 to 4 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject
Heat-inactivated specimen Reject

Method Name

Immunoblot Microarray

Forms

If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:

-General Request (T239)

-Infectious Disease Serology Test Request (T916)