Sign in →

Test Code LAB10144 Streptococcus Group A PCR

Performing Section

Microbiology

Purpose/Principle

In this assay, DNA extracted from patient samples is subjected to real-time PCR amplification using
primers and a fluorescent probe directed against a target sequence in the Strep A genome (spy1258) (Kodani, et al 2011). The product is detected on an Applied Biosystems 7500 Taqman™ instrument using 5’-nuclease methodology. An exogenous positive control is co-amplified in each reaction to determine extraction efficiency and detect inhibition. Results are reported as Strep A Detected or Not Detected.

Special Collection Notes

Collect specimen according to standard operating procedure.

Tissues, Aspirates, Fluids, and other Sterile Specimens: Collect specimen aseptically into a sterile specimen container.

Collect an aerobic culture swab using a COPAN ESwab. DO NOT collect with MRSA swab. Throat swabs are NOT acceptable.

Specimen Type

Tissue/Aspirate/Fluid/Other Sterile Specimen:

Sterile Container

 

Swab:

Aerobic Swab

Specimen Volume

Aspirate/Fluid
Minimum:0.5 mL

Processing Instructions

Store and send ambient ASAP/STAT. Specimen must arrive to the lab within 24 hrs of collection.

Temperature

Ambient

Test Components

Streptococcus Group A Qual

Reference Range

Streptococcus Group A Qual

Not Detected

TAT

72 hours

Sample Stability

Ambient: 24 hours

Aliases

STREP A
STREP A PCR
BSGA

CPT

87651